Type: Hall Type;
Output Signal Type: Analog Output;
Production Process: SemiConductor Integrated;
Material: Plastic;
Accuracy Grade: 1.0G;
Application: Smart Grid DC Transmission;
IP Rating: IP44;
Customized: Customized;
Rated Input: 50/100/200/300/400/600A;
Measuring Range: 0~+-900A;
Supply Voltage: DC +-12~15V;
Output Voltage: +-4.0V;
Offset Voltage: @IP=0, T=25c < +-25 Mv;
Power Consumption: 15mA;
Primary Through-Hole: D21.0+-0.15mm;
Plastic Material: PBT G30/G15, UL94-V0;
|
Type: Rogowski;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Metal;
Accuracy Grade: 0.5G;
Application: Csn Be Used in Many Cases;
IP Rating: IP67;
Customized: Customized;
Current Range(RMS): 0-100ka AC;
Output Signal(Di/Dt): 333mv/Ka@50Hz;
Accuracy(Typ.): Calibrated <0.5% (Central Position, 25℃);
Linearity (10% to 100% of Range): ±0.2% of Reading;
Bandwidth (-3dB): 1Hz to 100kHz;
Internal Resistance: 80 ± 10% Ohms/400mm;
Conductor Position Sensitivity: ±1% of Reading;
Output Sensitivity Tolerance: ±2%;
Thicker Flexible Rogowski Coil: Thicker Flexible Rogowski Coil;
|
Type: Rogowski;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Metal;
Accuracy Grade: 0.5G;
Application: Csn Be Used in Many Cases;
IP Rating: IP67;
Customized: Customized;
Current Range(RMS): 0-100ka AC;
Output Signal(Di/Dt): 50mv/Ka@50Hz,60mv/Ka@60Hz;
Accuracy(Typ.): Calibrated <0.5% (Central Position, 25℃);
Linearity (10% to 100% of Range): ±0.2% of Reading;
Bandwidth (-3dB): 1Hz to 100kHz;
Internal Resistance: 80 ± 10% Ohms/400mm;
Conductor Position Sensitivity: ±1% of Reading;
Output Sensitivity Tolerance: ±2%;
Thicker Flexible Rogowski Coil: Thicker Flexible Rogowski Coil;
|
Type: Rogowski;
Output Signal Type: Analog Output;
Production Process: Rogowski Coil Uniformly Wound with Enameled Wire;
Material: Coil and Signal Processing Circuit;
Accuracy Grade: Calibrated <0.5% (Central Positi;
Application: Power Monitoring & Control, Measuring Device;
IP Rating: IP68;
Customized: Customized;
|
Type: Rogowski;
Output Signal Type: Analog Output;
Production Process: Rogowski Coil;
Material: Coil and Signal Processing Circuit;
Accuracy Grade: Calibrated <0.5% (Central Positi;
Application: Power Monitoring & Control, Measuring Device;
IP Rating: IP67;
Customized: Customized;
Rated Current: 100A,600A,3000A,6000A...(Unlimited);
Mrc-16: Inner Diameter 16mm;
Mrc-24: Inner Diameter 24mm;
Mrc-36: Inner Diameter 36mm;
Mrc-50: Inner Diameter 50mm;
Ratio: Calibrated 22.5mv/Ka@50Hz, 50mv/Ka@50Hz;
Coil Section: 6mm;
Lead Length(Default): 2 Meter;
Read Accuracy: 0.5%Class;
Internal Resistance: 50-250 Ω
Position Error: Less Than 1%;
Phase Error: Less Than 0.5°;
Linearity: ±0.1%;
Bandwidth(3dB): 1Hz-20kHz;
Operating Temperature: -40℃-85℃;
|